<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Post - Normatempo</title>
	<atom:link href="https://www.normatempo.org/tag/post/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.normatempo.org</link>
	<description>Verifiche impianti di messa a terra e attrezzature di lavoro</description>
	<lastBuildDate>Tue, 29 Nov 2022 16:31:55 +0000</lastBuildDate>
	<language>it-IT</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.1.1</generator>

<image>
	<url>https://www.normatempo.org/wp-content/uploads/2022/09/logo-normatempo-bianco_piccolo-100x100.png</url>
	<title>Post - Normatempo</title>
	<link>https://www.normatempo.org</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>UNI/TS 11325-10: la nuova norma sulle attrezzature a pressione</title>
		<link>https://www.normatempo.org/impianti-a-pressione-gvr/units-11325-10-la-nuova-norma-sulle-attrezzature-a-pressione/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=units-11325-10-la-nuova-norma-sulle-attrezzature-a-pressione</link>
		
		<dc:creator><![CDATA[deslab_ut72]]></dc:creator>
		<pubDate>Wed, 05 Dec 2018 11:17:00 +0000</pubDate>
				<category><![CDATA[IMPIANTI A PRESSIONE GVR]]></category>
		<category><![CDATA[NEWS]]></category>
		<category><![CDATA[Post]]></category>
		<category><![CDATA[Standard]]></category>
		<category><![CDATA[WordPress]]></category>
		<guid isPermaLink="false">https://demo.themedraft.net/wp/induxter/?p=99</guid>

					<description><![CDATA[<p>Una nuova norma è disponibile per gli operatori del settore verifiche periodiche impianti a pressione: il 18 ottobre 2018 è stata pubblicata UNI/TS 11325-10 ovvero&#160;“Attrezzature a pressione – Messa in servizio e utilizzazione delle attrezzature e degli insiemi a pressione. Parte 10: Sorveglianza dei generatori di vapore e/o acqua surriscaldata esclusi dal campo di applicazione [&#8230;]</p>
<p>The post <a href="https://www.normatempo.org/impianti-a-pressione-gvr/units-11325-10-la-nuova-norma-sulle-attrezzature-a-pressione/">UNI/TS 11325-10: la nuova norma sulle attrezzature a pressione</a> first appeared on <a href="https://www.normatempo.org">Normatempo</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="99" class="elementor elementor-99">
									<section class="elementor-section elementor-top-section elementor-element elementor-element-1290e6d6 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="1290e6d6" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3bebc25c" data-id="3bebc25c" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
								<div class="elementor-element elementor-element-1dcfd014 elementor-widget elementor-widget-text-editor" data-id="1dcfd014" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
			<style>/*! elementor - v3.7.4 - 31-08-2022 */
.elementor-widget-text-editor.elementor-drop-cap-view-stacked .elementor-drop-cap{background-color:#818a91;color:#fff}.elementor-widget-text-editor.elementor-drop-cap-view-framed .elementor-drop-cap{color:#818a91;border:3px solid;background-color:transparent}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap{margin-top:8px}.elementor-widget-text-editor:not(.elementor-drop-cap-view-default) .elementor-drop-cap-letter{width:1em;height:1em}.elementor-widget-text-editor .elementor-drop-cap{float:left;text-align:center;line-height:1;font-size:50px}.elementor-widget-text-editor .elementor-drop-cap-letter{display:inline-block}</style>				<p style="text-align: justify;">Una nuova norma è disponibile per gli operatori del settore <strong>verifiche periodiche impianti a pressione</strong>: il 18 ottobre 2018 è stata pubblicata UNI/TS 11325-10 ovvero <em>“Attrezzature a pressione – Messa in servizio e utilizzazione delle attrezzature e degli insiemi a pressione. Parte 10: Sorveglianza dei generatori di vapore e/o acqua surriscaldata esclusi dal campo di applicazione della UNI/TS 11325-3”.</em><em> </em></p>
<p style="text-align: justify;">La nuova specifica tecnica definisce le modalità di sorveglianza delle attrezzature a pressione, a focolare o altro tipo di riscaldamento con rischio di surriscaldamento, destinate alla generazione di vapore d’acqua e/o di acqua surriscaldata a temperatura maggiore di 110° C e a pressione massima ammissibile maggiore di 0,5 bar rientranti nel campo di applicazione del D.M. 329/2004 ma esclusi dalla UNI/TS 11325-3.</p>
<p style="text-align: justify;">Tali attrezzature devono avere le seguenti caratteristiche:</p>
<ul>
<li style="text-align: justify;">generatori di vapore e/o acqua surriscaldata a sorgente termica diversa dal fuoco a condizione che le membrature soggette a pressione, a contatto con il fluido riscaldante, siano progettate per una temperatura non inferiore a quella del fluido di riscaldamento stesso;</li>
<li style="text-align: justify;"> generatori di vapore e/o acqua surriscaldata ad attraversamento meccanico di limitata potenzialità aventi PS x V ≤ 3000 bar x litri e PS ≤ 12 bar;</li>
<li style="text-align: justify;">generatori di vapore a bassa pressione aventi PS ≤ 1 bar, superficie di riscaldamento ≤ 100 m2 e potenzialità ≤ 2 t/h;</li>
<li style="text-align: justify;">generatori di acqua surriscaldata a bassa pressione aventi PS ≤ 5 bar, temperatura massima dell&#8217;acqua ≤ 120 °C e potenzialità ≤ 2 t/h;</li>
<li style="text-align: justify;">generatori di vapore e/o acqua surriscaldata a riscaldamento elettrico.</li>
</ul>
<p style="text-align: justify;">Il documento, realizzato dal Comitato Termotecnico Italiano (Ente Federato UNI), è un punto di riferimento importante per l’intero comparto delle <strong>verifiche periodiche attrezzature di lavoro</strong> anche perché annovera le seguenti norme:</p>
<ul>
<li style="text-align: justify;">UNI EN 11325-3 Messa in servizio ed utilizzazione delle attrezzature e degli insiemi a pressione. Parte 3: sorveglianza dei generatori di vapore e/o acqua surriscaldata;</li>
<li style="text-align: justify;">UNI EN 12952-12 Caldaie a tubi d&#8217;acqua e installazioni ausiliarie &#8211; Parte 12: Requisiti relativi alla qualità dell&#8217;acqua di alimentazione e dell&#8217;acqua in caldaia;</li>
<li style="text-align: justify;">UNI EN 12953-10 Caldaie a tubi da fumo &#8211; Parte 10: Requisiti relativi alla qualità dell&#8217;acqua di alimentazione e dell&#8217;acqua in caldaia.</li>
</ul>						</div>
				</div>
					</div>
		</div>
							</div>
		</section>
							</div><p>The post <a href="https://www.normatempo.org/impianti-a-pressione-gvr/units-11325-10-la-nuova-norma-sulle-attrezzature-a-pressione/">UNI/TS 11325-10: la nuova norma sulle attrezzature a pressione</a> first appeared on <a href="https://www.normatempo.org">Normatempo</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Serbatoi GPL: nuovi chiarimenti dal Mise sulla riqualificazione per interramento</title>
		<link>https://www.normatempo.org/impianti-a-pressione-gvr/serbatoi-gpl-nuovi-chiarimenti-dal-mise-sulla-riqualificazione-per-interramento/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=serbatoi-gpl-nuovi-chiarimenti-dal-mise-sulla-riqualificazione-per-interramento</link>
		
		<dc:creator><![CDATA[deslab_ut72]]></dc:creator>
		<pubDate>Sun, 11 Nov 2018 11:11:00 +0000</pubDate>
				<category><![CDATA[IMPIANTI A PRESSIONE GVR]]></category>
		<category><![CDATA[Post]]></category>
		<category><![CDATA[Single]]></category>
		<category><![CDATA[Video]]></category>
		<category><![CDATA[WordPress]]></category>
		<guid isPermaLink="false">https://demo.themedraft.net/wp/induxter/?p=95</guid>

					<description><![CDATA[<p>Arrivano dal Mise nuove istruzioni riguardanti il settore verifiche impianti a pressione: con il comunicato del 17 settembre 2018, il Ministero per lo Sviluppo Economico precisa le “Procedure di riqualificazione per interramento di serbatoi GPL di capacità inferiore a 13 mc”. La competente “Direzione generale per il mercato, la concorrenza, il consumatore, la vigilanza e la [&#8230;]</p>
<p>The post <a href="https://www.normatempo.org/impianti-a-pressione-gvr/serbatoi-gpl-nuovi-chiarimenti-dal-mise-sulla-riqualificazione-per-interramento/">Serbatoi GPL: nuovi chiarimenti dal Mise sulla riqualificazione per interramento</a> first appeared on <a href="https://www.normatempo.org">Normatempo</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="95" class="elementor elementor-95">
									<section class="elementor-section elementor-top-section elementor-element elementor-element-495a3ac8 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="495a3ac8" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6b05c560" data-id="6b05c560" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
								<div class="elementor-element elementor-element-65bfd88f elementor-widget elementor-widget-text-editor" data-id="65bfd88f" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p style="text-align: justify;">Arrivano dal Mise nuove istruzioni riguardanti il settore <strong><a href="https://www.normatempo.org/attrezzature-lavoro-impianti">verifiche impianti a pressione</a></strong>: con il comunicato del 17 settembre 2018, il Ministero per lo Sviluppo Economico precisa le “<em>Procedure di riqualificazione per interramento di serbatoi GPL di capacità inferiore a 13 mc</em>”.</p><p style="text-align: justify;">La competente “Direzione generale per il mercato, la concorrenza, il consumatore, la vigilanza e la normativa tecnica” in qualità di Autorità di vigilanza sul mercato, ribadisce che “<em>ogni intervento di ricondizionamento dei serbatoi GPL per “interramento” si configura come “modifica” e, pertanto, deve essere realizzato in conformità alle disposizioni applicabili per le nuove costruzioni, assoggettando l’attrezzatura ad una procedura di valutazione della conformità in ottemperanza al decreto legislativo 93/2000, come modificato dal d.lgs. 26/2016 di attuazione della direttiva 2014/68/UE “attrezzature a pressione –  PED”</em>.</p><p style="text-align: justify;">Tradotta dal punto di vista pratico, la suddetta normativa stabilisce che, allo scopo di non esporre gli utenti a rischi potenziali, eventuali attività di interramento di serbatoi GPL devono essere posti in essere, predisponendo le misure di messa in sicurezza, ad opera di “Organismi notificati” sulla Direttiva “attrezzature a pressione – PED” ai sensi del D.lgs 93/2000, tramite il rilascio di una nuova Dichiarazione di conformità e marcatura CE.</p><p style="text-align: justify;">In sostanza, i PED, ovvero le attrezzature a pressione (caldaie, recipienti a pressione, tubazioni ed accessori) o gli insiemi di impianti, possono essere immessi sul mercato europeo e messi in funzione solo se soddisfano i requisiti del D.lgs 26/2016 anche in caso di installazione/manutenzione e di impiego conforme alla loro destinazione.</p><p style="text-align: justify;">I recenti chiarimenti del Mise relativi alla direttiva PED rappresentano dunque un riferimento importante per il comparto <strong><a href="https://www.normatempo.org/verifiche-periodiche-attrezzature-di-lavoro">verifiche periodiche attrezzature di lavoro</a></strong> ai fini dell’accertamento della conformità degli interventi di interramento dei recipienti GPL di capacità inferiore a 13 mc alle ultime disposizioni legislative vigenti in ambito comunitario.</p>						</div>
				</div>
					</div>
		</div>
							</div>
		</section>
							</div><p>The post <a href="https://www.normatempo.org/impianti-a-pressione-gvr/serbatoi-gpl-nuovi-chiarimenti-dal-mise-sulla-riqualificazione-per-interramento/">Serbatoi GPL: nuovi chiarimenti dal Mise sulla riqualificazione per interramento</a> first appeared on <a href="https://www.normatempo.org">Normatempo</a>.</p>]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>Guida Inail palchi: un valido supporto per la sicurezza opere temporanee</title>
		<link>https://www.normatempo.org/news/guida-inail-palchi-spettacoli-un-valido-supporto-per-la-sicurezza-opere-temporanee/?utm_source=rss&#038;utm_medium=rss&#038;utm_campaign=guida-inail-palchi-spettacoli-un-valido-supporto-per-la-sicurezza-opere-temporanee</link>
		
		<dc:creator><![CDATA[deslab_ut72]]></dc:creator>
		<pubDate>Thu, 02 Aug 2018 04:38:00 +0000</pubDate>
				<category><![CDATA[NEWS]]></category>
		<category><![CDATA[Post]]></category>
		<category><![CDATA[Standard]]></category>
		<category><![CDATA[WordPress]]></category>
		<guid isPermaLink="false">https://demo.themedraft.net/wp/induxter/?p=71</guid>

					<description><![CDATA[<p>Con la stagione estiva sono sempre più numerosi gli eventi pubblici organizzati dagli enti locali. Spettacoli e concerti animano le serate delle nostre città, ma dietro al divertimento c’è chi lavora sodo non senza qualche rischio per la propria salute. Negli ultimi anni l’attività di&#160;verifica attrezzature di lavoro&#160;annovera anche le operazioni di montaggio, smontaggio e [&#8230;]</p>
<p>The post <a href="https://www.normatempo.org/news/guida-inail-palchi-spettacoli-un-valido-supporto-per-la-sicurezza-opere-temporanee/">Guida Inail palchi: un valido supporto per la sicurezza opere temporanee</a> first appeared on <a href="https://www.normatempo.org">Normatempo</a>.</p>]]></description>
										<content:encoded><![CDATA[<div data-elementor-type="wp-post" data-elementor-id="71" class="elementor elementor-71">
									<section class="elementor-section elementor-top-section elementor-element elementor-element-42983ec1 elementor-section-boxed elementor-section-height-default elementor-section-height-default" data-id="42983ec1" data-element_type="section">
						<div class="elementor-container elementor-column-gap-default">
					<div class="elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-5f0d0f12" data-id="5f0d0f12" data-element_type="column">
			<div class="elementor-widget-wrap elementor-element-populated">
								<div class="elementor-element elementor-element-79e35199 elementor-widget elementor-widget-text-editor" data-id="79e35199" data-element_type="widget" data-widget_type="text-editor.default">
				<div class="elementor-widget-container">
							<p style="text-align: justify;">Con la stagione estiva sono sempre più numerosi gli eventi pubblici organizzati dagli enti locali. Spettacoli e concerti animano le serate delle nostre città, ma dietro al divertimento c’è chi lavora sodo non senza qualche rischio per la propria salute. Negli ultimi anni l’attività di <strong><a href="https://www.normatempo.org/">verifica attrezzature di lavoro</a></strong> annovera anche le operazioni di montaggio, smontaggio e allestimento delle opere temporanee impiegate per la realizzazione di spettacoli, mostre ed eventi culturali: in altri termini, i palchi.</p>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;">Con la guida pubblicata lo scorso anno intitolata <em>“Palchi per spettacoli ed eventi similari. Leggi, norme e guide. Stato dell’arte in Italia, Inghilterra e USA”</em>, l’Inail fornisce informazioni utili agli operatori pubblici e privati di questo settore, attingendole dal contesto nazionale ed internazionale. Il documento contiene infatti leggi, norme e guide in Italia, USA e Inghilterra.</p>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;">Tutte le attività connesse alle opere temporanee sono potenzialmente rischiose per gli addetti al montaggio, smontaggio e allestimento degli impianti scenotecnici per una serie di motivi: il numero cospicuo di lavoratori anche di diversa nazionalità, la presenza contemporanea di più imprese esecutrici nell’area di lavoro, la necessità di completare i lavori in tempi brevi e in spazi ristretti e, infine, le diverse caratteristiche del luogo dove vengono installate e delle condizioni meteorologiche.</p>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;">Dal punto di vista legislativo, in Italia abbiamo tre riferimenti normativi che regolamentano la sicurezza sui palchi, ovvero il Decreto del Fare (DL 69/2013) che di fatto estende l’applicazione del Titolo IV – Cantieri temporanei o mobili – del D.lgs 81/08 agli spettacoli musicali, cinematografici, teatrali e manifestazioni fieristiche; c’è poi il d.i. 22 luglio 2014 (Decreto Palchi e fiere) e la circolare ministeriale n. 35 del 24 dicembre 2014 contenente istruzioni operative tecnico-organizzative per l’allestimento e la gestione delle opere temporanee.</p>
<p style="text-align: justify;"> </p>
<p style="text-align: justify;">Proprio come i cantieri mobili, i palchi sono a tutti gli effetti luoghi di lavoro soggetti anche a controlli, alla stregua delle normali <strong><a href="https://www.normatempo.org/verifiche-periodiche-attrezzature-di-lavoro">verifiche periodiche attrezzature di lavoro</a></strong>. Il documento, oltre ad individuare le diverse tipologie di palchi e le figure coinvolte, a fornire valide indicazioni inerenti progettazione, analisi strutturale e requisiti formativi del personale, individua le diverse tipologie di verifiche.</p>						</div>
				</div>
					</div>
		</div>
							</div>
		</section>
							</div><p>The post <a href="https://www.normatempo.org/news/guida-inail-palchi-spettacoli-un-valido-supporto-per-la-sicurezza-opere-temporanee/">Guida Inail palchi: un valido supporto per la sicurezza opere temporanee</a> first appeared on <a href="https://www.normatempo.org">Normatempo</a>.</p>]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
